D DDC SOLUTIONS

Live / Allowed — Notice of allowance issued (as of 31 Mar 2026)

What this means for you

Approved and waiting on proof of use. It will register unless the applicant drops it, and its 18 Oct 2024 filing date already counts against anyone who files later.

Record

Serial number
98808919
Mark type
Design + words
Filed
18 Oct 2024
Published for opposition
03 Feb 2026
Attorney of record
Anna Kurian Shaw

Goods and services

  • Class 006 — Metal goods: Metal panel systems comprising metal walls, ceiling, floor and door panels and metal mounting accessories therefor, namely, brackets, for use in controlling the flow of cooling air in data centers and computer rooms; metal cable trays used for computer servers and electrical and electronic equipment; pre-fabricated metal buildings for data center applications; metal shelter structures for computer servers and electrical and electronic equipment
  • Class 009 — Scientific and electric apparatus: Electric control panels for monitoring electrical power system critical system alarms; cooling devices for computer hardware and telecommunication equipment, namely, internal cooling fans; computer hardware and downloadable computer software for data center infrastructure configuration and management; data center and computer room infrastructure management systems comprised primarily of electronic controller for controlling air conditioning and temperature, mass air flow sensors, downloadable computer software for monitoring data center and computer room infrastructure equipment, and also containing a cooling system comprised primarily of air cooling apparatus, cooling evaporators, air conditioning units, electric fans, water cooling towers and associated electronic fan controls being electronic control circuits for fans, air conditioning controls, cabinets specially adapted for computer hardware equipment, and storage racks, curtains, doors of metal and containment panels for use with computer systems, all sold together as a unit; data center monitoring and control systems, namely, systems comprised primarily of microprocessor based hardware and downloadable computer software used to monitor electrical and electronic equipment, and climate conditions in a data center, telecommunication center, computer room or electronic equipment room environment; electronic controls for server racks and data center cooling units; enclosures, cabinets and mounting racks for computer servers and electrical and electronic equipment; fan trays for cooling of telecommunication devices; electronic thermostat regulating devices in the nature of thermostatic and airflow control modules for control of heat within enclosed electronic equipment racks and cabinets; climate control and cooling systems for telecom and data communication equipment, consisting of thermostats for cooling equipment and a programmable logic controller (plc) with input and output features for temperature; microprocessor based hardware and downloadable computer software used to monitor and control cooling and air handler units for data centers and other computer and telecommunications equipment applications; computer server mounting racks; computer server mounting racks incorporating integrated cooling units; downloadable computer software for data center infrastructure configuration and management
  • Class 011 — Environmental control apparatus: Air handlers for cooling data centers; cooling units and systems comprised of evaporative cooling units and air conditioners for computer server racks and computer data centers; evaporative cooling units for computers and computer rooms; air conditioning and air cooling apparatus and instruments, namely, condensers for use in cooling data centers, computer rooms and other computer and electronic equipment applications; dehumidifiers for use in cooling data centers, computer rooms and other computer and electronic equipment applications
  • Class 037 — Building construction and repair services: Installation, maintenance and repair of data center cooling systems; installation, maintenance and repair of computer and telecommunications equipment; installation, maintenance and repair of computer room air conditioning (crac) systems; maintenance and comprehensive preventive maintenance services of air conditioning for data centers and computer rooms
  • Class 040 — Treatment of materials: Custom manufacture of equipment for data centers
  • Class 042 — Scientific and technological services: Air conditioning maintenance assessment services for the performance and reliability of air conditioning systems for data centers and computer rooms; engineering services, namely, providing technical assessment of the performance, reliability, maintenance and configuration of data center cooling systems; remote monitoring of the functioning and use of data center and computer room electrical equipment, electrical power systems, and data center and computer room heating, ventilating and air conditioning apparatus; design for others of equipment for data center facilities

Owner

Prosecution history

  • 31 Mar 2026 — NOA E-MAILED - SOU REQUIRED FROM APPLICANT
  • 03 Feb 2026 — OFFICIAL GAZETTE PUBLICATION CONFIRMATION E-MAILED
  • 03 Feb 2026 — PUBLISHED FOR OPPOSITION
  • 28 Jan 2026 — NOTIFICATION OF NOTICE OF PUBLICATION E-MAILED
  • 08 Jan 2026 — APPROVED FOR PUB - PRINCIPAL REGISTER
  • 27 Oct 2025 — TEAS/EMAIL CORRESPONDENCE ENTERED
  • 27 Oct 2025 — CORRESPONDENCE RECEIVED IN LAW OFFICE
  • 27 Oct 2025 — TEAS RESPONSE TO OFFICE ACTION RECEIVED
  • 30 Jun 2025 — APPLICATION EXTENSION GRANTED/RECEIPT PROVIDED
  • 30 Jun 2025 — APPLICATION EXTENSION TO RESPONSE PERIOD - RECEIVED
  • 27 Apr 2025 — NOTIFICATION OF NON-FINAL ACTION E-MAILED
  • 27 Apr 2025 — NON-FINAL ACTION E-MAILED
  • 27 Apr 2025 — NON-FINAL ACTION WRITTEN
  • 21 Apr 2025 — ASSIGNED TO EXAMINER
  • 20 Apr 2025 — NOTICE OF DESIGN SEARCH CODE E-MAILED

View this trademark record on Marksy