Serial 87734562
Live / Registered — Registered — Section 8 accepted (as of 11 Dec 2025)
What this means for you
Registered since 04 Sept 2018. The owner can stop confusingly similar uses in the classes it covers.
Record
- Serial number
- 87734562
- Registration number
- 5557409
- Mark type
- Design / logo
- Filed
- 26 Dec 2017
- Registered
- 04 Sept 2018
- Attorney of record
- Leo M. Loughlin
Goods and services
- Class 001 — Chemicals: Chemicals for use in industry and science; reagents for use in scientific apparatus for chemical or biological analysis; reagents for analysis apparatus; diagnostic reagents for scientific research
- Class 005 — Pharmaceuticals: Medical diagnostic reagents for use in clinical diagnosis; medical diagnostic reagents, namely, reagents for use in analysis apparatus for clinical diagnosis; diagnostic and analysis reagents for medical use in scientific and clinical laboratories; diagnostic and analysis reagents for medical use; medical diagnostic reagents, namely, immunoassay reagents for clinical diagnostic use; reagents for medical use
- Class 009 — Scientific and electric apparatus: Analysis apparatus and instruments for scientific or non-medical use, namely, microplate readers and biological cell imaging instruments in the nature of microscopes; scientific apparatus, namely, a cell imaging device for use in scientific, laboratory or medical research in the nature of fluorescence imaging cameras; laboratory robots, namely, robots for laboratory automation and robots for the automation of analysis processes; laboratory instruments in the nature of pipetting devices and distribution devices not for medical use, namely, automated pipetting apparatus, sampling devices for sampling liquid specimen, dilutors with motor driven syringe; disposable pipette tips for laboratory use; laboratory equipment and supplies in the nature of disposable containers, namely, [ sample tubes, test tubes, reagent bottles, ] reagent troughs [ and Petri dishes ] for reagents [ and samples ] in connection with pipetting devices; [ cell counting chambers for counting biological cells in connection with absorption measuring apparatus, luminescence measuring apparatus and fluorescence measuring apparatus; ] absorption measuring apparatus, luminescence measuring apparatus and fluorescence measuring apparatus; [ and laser scanners; ] micro-plate washers; all the aforesaid equipment for use in laboratories; software for monitoring the above-mentioned apparatus and for the analysis of measurement results
- Class 010 — Medical apparatus: Analysis apparatus and instruments for clinical diagnostic use and veterinary use, namely, pipetting devices, absorption measuring apparatus, luminescence measuring apparatus and fluorescence measuring apparatus; [ and laser scanners; ] all the aforesaid goods for medical laboratories
- Class 042 — Scientific and technological services: [ Scientific and ] technological services, namely, [ scientific laboratory services and research services as well as ] technical design services; [ relating thereto; industrial analysis and research services in the field of chemistry and life sciences; ] planning and design of laboratory automated systems; design and development of automation equipment for laboratories and analysis equipment; development of computer [ hardware and ] software
Owner
- TECAN TRADING AG, MÄNNEDORF, CH
- Tecan Group AG, Männedorf, CH
- Tecan Group AG, Männedorf, CH
Prosecution history
- 11 Dec 2025 — NOTICE OF ACCEPTANCE OF SEC. 8 - E-MAILED
- 11 Dec 2025 — REGISTERED - SEC. 8 (6-YR) ACCEPTED
- 10 Dec 2025 — TEAS RESPONSE TO OFFICE ACTION-POST REG RECEIVED
- 12 Jun 2025 — POST REGISTRATION ACTION MAILED - SEC. 8
- 12 Jun 2025 — CASE ASSIGNED TO POST REGISTRATION PARALEGAL
- 04 Mar 2025 — TEAS SECTION 8 RECEIVED
- 04 Sept 2023 — COURTESY REMINDER - SEC. 8 (6-YR) E-MAILED
- 19 Dec 2022 — TEAS CHANGE OF CORRESPONDENCE RECEIVED
- 19 Dec 2022 — TEAS CHANGE OF DOMESTIC REPRESENTATIVES ADDRESS
- 19 Dec 2022 — ATTORNEY/DOM.REP.REVOKED AND/OR APPOINTED
- 19 Dec 2022 — TEAS REVOKE/APP/CHANGE ADDR OF ATTY/DOM REP RECEIVED
- 17 Feb 2021 — AUTOMATIC UPDATE OF ASSIGNMENT OF OWNERSHIP
- 06 Jan 2021 — APPLICANT/CORRESPONDENCE CHANGES (NON-RESPONSIVE) ENTERED
- 06 Jan 2021 — TEAS CHANGE OF CORRESPONDENCE RECEIVED
- 06 Jan 2021 — TEAS CHANGE OF DOMESTIC REPRESENTATIVES ADDRESS